Laser/Eddy Current Data Acquisition
The problem:
Laser profiling sensors are well suited for detecting and
measuring surface features, such as topography, roughness, discoloration
and surface-breaking cracks. They cannot, however, detect sub-surface features,
such as inclusions or the presence of external support plates.
The solution:
LTC
has developed several laser-based surface profiling and laser-scanned penetrant inspection (LSPI™) sensors that also include
integrated eddy current (EC) sensors. In some cases, the EC sensor
(bobbin coil) is used for the detection of features such as external
support plates or weldments. In other cases, LTC has
integrated single-point, rotary eddy current sensors for the detection
of features such as subsurface cracks. By combining the technologies
of laser-based profiling and eddy current flaw detection, virtually
100% of the tube volume can be interrogated in a single scan —
locating and mapping ID, OD and subsurface flaws.

Combined Laser
Profile/EC image of tube ovality |